vc707 axi: move addresses to line up with ChipLink
This commit is contained in:
		| @@ -193,7 +193,7 @@ class VC707AXIToPCIeX1(implicit p:Parameters) extends LazyModule | ||||
|  | ||||
|   val slave = AXI4SlaveNode(Seq(AXI4SlavePortParameters( | ||||
|     slaves = Seq(AXI4SlaveParameters( | ||||
|       address       = List(AddressSet(0x60000000L, 0x1fffffffL)), | ||||
|       address       = List(AddressSet(0x40000000L, 0x1fffffffL)), | ||||
|       resources     = Seq(Resource(device, "ranges")), | ||||
|       executable    = true, | ||||
|       supportsWrite = TransferSizes(1, 128), | ||||
| @@ -202,7 +202,7 @@ class VC707AXIToPCIeX1(implicit p:Parameters) extends LazyModule | ||||
|  | ||||
|   val control = AXI4SlaveNode(Seq(AXI4SlavePortParameters( | ||||
|     slaves = Seq(AXI4SlaveParameters( | ||||
|       address       = List(AddressSet(0x50000000L, 0x03ffffffL)), | ||||
|       address       = List(AddressSet(0x2000000000L, 0x3ffffffL)), // when truncated to 32-bits, is 0 | ||||
|       resources     = device.reg("control"), | ||||
|       supportsWrite = TransferSizes(1, 4), | ||||
|       supportsRead  = TransferSizes(1, 4), | ||||
| @@ -402,13 +402,13 @@ class VC707AXIToPCIeX1(implicit p:Parameters) extends LazyModule | ||||
|     """  | ||||
|       create_ip -vendor xilinx.com -library ip -version 2.8 -name axi_pcie -module_name vc707axi_to_pcie_x1 -dir $ipdir -force | ||||
|       set_property -dict [list \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_0             {0x60000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_0             {0x40000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_1             {0x00000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_2             {0x00000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_3             {0x00000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_4             {0x00000000} \ | ||||
|       CONFIG.AXIBAR2PCIEBAR_5             {0x00000000} \ | ||||
|       CONFIG.AXIBAR_0                     {0x60000000} \ | ||||
|       CONFIG.AXIBAR_0                     {0x40000000} \ | ||||
|       CONFIG.AXIBAR_1                     {0xFFFFFFFF} \ | ||||
|       CONFIG.AXIBAR_2                     {0xFFFFFFFF} \ | ||||
|       CONFIG.AXIBAR_3                     {0xFFFFFFFF} \ | ||||
| @@ -420,7 +420,7 @@ class VC707AXIToPCIeX1(implicit p:Parameters) extends LazyModule | ||||
|       CONFIG.AXIBAR_AS_3                  {false} \ | ||||
|       CONFIG.AXIBAR_AS_4                  {false} \ | ||||
|       CONFIG.AXIBAR_AS_5                  {false} \ | ||||
|       CONFIG.AXIBAR_HIGHADDR_0            {0x7FFFFFFF} \ | ||||
|       CONFIG.AXIBAR_HIGHADDR_0            {0x5FFFFFFF} \ | ||||
|       CONFIG.AXIBAR_HIGHADDR_1            {0x00000000} \ | ||||
|       CONFIG.AXIBAR_HIGHADDR_2            {0x00000000} \ | ||||
|       CONFIG.AXIBAR_HIGHADDR_3            {0x00000000} \ | ||||
| @@ -440,14 +440,14 @@ class VC707AXIToPCIeX1(implicit p:Parameters) extends LazyModule | ||||
|       CONFIG.BAR2_SIZE                    {8} \ | ||||
|       CONFIG.BAR2_TYPE                    {N/A} \ | ||||
|       CONFIG.BAR_64BIT                    {true} \ | ||||
|       CONFIG.BASEADDR                     {0x50000000} \ | ||||
|       CONFIG.BASEADDR                     {0x00000000} \ | ||||
|       CONFIG.BASE_CLASS_MENU              {Bridge_device} \ | ||||
|       CONFIG.CLASS_CODE                   {0x060400} \ | ||||
|       CONFIG.COMP_TIMEOUT                 {50ms} \ | ||||
|       CONFIG.Component_Name               {design_1_axi_pcie_1_0} \ | ||||
|       CONFIG.DEVICE_ID                    {0x7111} \ | ||||
|       CONFIG.ENABLE_CLASS_CODE            {true} \ | ||||
|       CONFIG.HIGHADDR                     {0x53FFFFFF} \ | ||||
|       CONFIG.HIGHADDR                     {0x03FFFFFF} \ | ||||
|       CONFIG.INCLUDE_BAROFFSET_REG        {true} \ | ||||
|       CONFIG.INCLUDE_RC                   {Root_Port_of_PCI_Express_Root_Complex} \ | ||||
|       CONFIG.INTERRUPT_PIN                {false} \ | ||||
|   | ||||
		Reference in New Issue
	